LPT40 Series Artesyn 40-55 Watt AC-DC Power Supplies

  • по запросу
  • Производитель: Artesyn
  • Модель: LPT40 Series
Модель Цена На складе, шт Количество
LPT41 по запросу по запросу
LPT42 по запросу по запросу
LPT43 по запросу по запросу
LPT44 по запросу по запросу
LPT45 по запросу по запросу
LPT46 по запросу по запросу
LPT47 по запросу по запросу

The LPT40 series of open-frame AC-DC power supplies comprises seven triple output models, covering a variety of standard voltages from -15 V to 24 Vdc. Each model accepts a universal input of 85—264 Vac or 120—300 Vdc. These compact switch-mode power supplies feature main output overvoltage protection and remote sense, with short-circuit protection on all outputs. Depending on the model, they provide up to 40 watts of output power with free air convection cooling and up to 55 watts with 30 CFM of forced air. Less than 1U high, LPT40 series power supplies are suitable for a variety of uses including test and measurement, single-board computers, telecommunications and networking.

Особенности

  • LPX40 enclosure kit available
  • Universal input
  • 3" x 5" footprint
  • Remote sense on main output
  • Built-in EMI filter
  • Low output ripple
  • Adjustable main output
  • Overvoltage protection
  • 110 KHz switching frequency
  • Terminal block option (-T)
  • Less than 1U high
  • Overload protection

Технические характеристики

  • Total Max Power:
    55 W
  • Total Max Current:
    8 A
  • Input Voltage:
    85 V to 264 V
  • Output Voltage:
    -15 V to 24 V
  • Outputs:
    Triple
  • Size (L x W x H):
    5.000" x 3.000" x 1.200"
  • Warranty:
    2 years
  • Operating Temperature:
    -20°C to +70°C

Electrical Specifications

  • Input
  • Output
  • Input current: 1 A max. (RMS) @ 115 Vac
  • Inrush current: < 18 A peak @ 115 Vac; < 36 A peak @ 230 Vac
  • EMI filter: FCC Class B conducted; CISPR 22 Class B conducted
  • Efficiency: 70% typical at full load (60% for LPT41)
  • Safety ground leakage current: < 0.5 mA @ 50/60 Hz, 264 Vac input
  • Frequency: 47 - 440 Hz
  • Input range: 85 - 264 Vac, 120 - 300 Vdc
  • Cross regulation: ± 2% on output 1; ± 5% on outputs 2, 3
  • Hold-up time: 20 ms @ 40 W load, 115 Vac nominal line
  • Remote sense: Compensates for 0.5 V lead drop min.
  • Adjustment range: -5, +10% minimum
  • Maximum power: 40 W for convection, (LPT41, 25 W); 55 W w/ 30 CFM
  • Overload protection: Short circuit protection and case overload
  • Overvoltage protection: 5.7 to 6.7 Vdc on main output LPT41: 3.6 to 4.6 V

Написать отзыв

Примечание: HTML разметка не поддерживается! Используйте обычный текст.

Гарантия

У нас вы можете получить онлайн-консультацию по выбору и комплектации, инструмента.

Обмен и возврат товара осуществляется в соответствии с положениями Закона о защите прав потребителей. Адрес точки приёма: 192019, г. Санкт-Петербург, ул. Смоляная, д.15, лит. А, пом. 24.

  • Информация о гарантии производителя
  • Найти сервисный центр по ремонту инструмента
  • Сертификаты продавца/производителя

ETK-135067